1,6-Hexamethylene Diamine (Hda) As a Urinary Biomarker for Dermal and Inhalation Exposure to 1,6-Hexamethylene Diisocyanate (Hdi) In Automotive Spray-Painters 1,6-Hexamethylene Diamine (Hda) As a Urinary Biomarker for Dermal and Inhalation Exposure to 1,6-Hexamethylene Diisocyanate (Hdi) In Automotive Spray-Painters

1,6-Hexamethylene Diamine (Hda) As a Urinary Biomarker for Dermal and Inhalation Exposure to 1,6-Hexamethylene Diisocyanate (Hdi) In Automotive Spray-Painters

    • $9.99
    • $9.99

Publisher Description

Urinary 1,6-hexamethylene diamine (HDA) has been indicated as a potential biomarker for systemic exposure to 1,6-hexamethylene diisocyanate (HDI). Our objective was to establish a quantitative and time-dependent relationship between urine HDA levels and inhalation and dermal exposure to HDI. Urine HDA levels, creatinine concentrations, and specific gravity along with dermal and breathing-zone levels of HDI were measured in automotive spray painters. Dermal exposure and inhalation exposure levels, adjusted for the type of respirator worn, and creatinine concentration were observed to be significant predictors of urine HDA levels. The use of coveralls, type of respirator worn, smoker status, type of painting booth, and multiple painters at the shop were found to significantly affect urine HDA. Our results indicate that urine HDA is a useful biomarker for systemic HDI exposure through the skin and lungs and emphasize the need for proper dermal and inhalation protection for workers.

GENRE
Science & Nature
RELEASED
2011
11 November
LANGUAGE
EN
English
LENGTH
139
Pages
PUBLISHER
Lulu.com
SELLER
Lulu Enterprises, Inc.
SIZE
603.8
KB

More Books Like This

Can Whole-Blood Samples Be Stored over 24 Hours Without Compromising Stability of C-Reactive Protein, Retinol, Ferritin, Folic Acid, And Fatty Acids in Epidemiologic Research?(Technical Briefs) (Clinical Report) Can Whole-Blood Samples Be Stored over 24 Hours Without Compromising Stability of C-Reactive Protein, Retinol, Ferritin, Folic Acid, And Fatty Acids in Epidemiologic Research?(Technical Briefs) (Clinical Report)
2005
Acute Exposure Guideline Levels for Selected Airborne Chemicals Acute Exposure Guideline Levels for Selected Airborne Chemicals
2004
[[Alpha].Sub.1]-Microglobulin Is Stable in Human Urine Ex Vivo (Letters) (Letter to the Editor) [[Alpha].Sub.1]-Microglobulin Is Stable in Human Urine Ex Vivo (Letters) (Letter to the Editor)
2002
Contemporary Practice in Clinical Chemistry Contemporary Practice in Clinical Chemistry
2020
Fundamentals of Analytical Toxicology Fundamentals of Analytical Toxicology
2020
Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor) Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor)
2006