Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor) Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor)

Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor‪)‬

Clinical Chemistry 2006, August, 52, 8

    • $5.99
    • $5.99

Publisher Description

To the Editor: Nephelometry is widely used for quantification of serum proteins. The main manufacturers of nephelometers, Beckman-Coulter and DadeBehring, recommend serum as a sample for most tests. For a limited number of tests, e.g., lipoprotein(a), they state that serum and heparin plasma can be used. Serum should be separated from contact with cells as soon as possible (1), but blood should be allowed to sit long enough for complete clot formation because inadequate clot formation with residual fibrin strands can clog the sampling pipette. Use of plasma circumvents these clotting-related problems. We therefore investigated whether lithium-heparin plasma can be used for nephelometric analysis of a whole array of serum proteins.

GENRE
Science & Nature
RELEASED
2006
1 August
LANGUAGE
EN
English
LENGTH
8
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SELLER
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
SIZE
188.4
KB

More Books Like This

Can Whole-Blood Samples Be Stored over 24 Hours Without Compromising Stability of C-Reactive Protein, Retinol, Ferritin, Folic Acid, And Fatty Acids in Epidemiologic Research?(Technical Briefs) (Clinical Report) Can Whole-Blood Samples Be Stored over 24 Hours Without Compromising Stability of C-Reactive Protein, Retinol, Ferritin, Folic Acid, And Fatty Acids in Epidemiologic Research?(Technical Briefs) (Clinical Report)
2005
Components of Total Measurement Error for Hemoglobin [A.Sub.1C] (Technical Briefs) (Clinical Report) Components of Total Measurement Error for Hemoglobin [A.Sub.1C] (Technical Briefs) (Clinical Report)
2001
Interlaboratory Variation of Plasma Total Homocysteine Measurements: Results of Three Successive Homocysteine Proficiency Testing Surveys (General Clinical Chemistry) Interlaboratory Variation of Plasma Total Homocysteine Measurements: Results of Three Successive Homocysteine Proficiency Testing Surveys (General Clinical Chemistry)
2002
Contemporary Practice in Clinical Chemistry (Enhanced Edition) Contemporary Practice in Clinical Chemistry (Enhanced Edition)
2020
Clinical Proteomics  Building a Robust End-to-End Proteomics Platform for Biomarker Discovery Clinical Proteomics  Building a Robust End-to-End Proteomics Platform for Biomarker Discovery
2013
Principles and Applications of Clinical Mass Spectrometry Principles and Applications of Clinical Mass Spectrometry
2018

More Books by Clinical Chemistry

Lowering Cutoffs for Initial and Confirmation Testing for Cocaine and Marijuana: Large-Scale Study of Effects on the Rates of Drug-Positive Results (Drug Monitoring and Toxicology) Lowering Cutoffs for Initial and Confirmation Testing for Cocaine and Marijuana: Large-Scale Study of Effects on the Rates of Drug-Positive Results (Drug Monitoring and Toxicology)
1997
Myocardial Infarction Redefined: Role of Cardiac Troponin Testing (Editorial) Myocardial Infarction Redefined: Role of Cardiac Troponin Testing (Editorial)
2001
Distribution of Fasting Plasma Insulin, Free Fatty Acids, And Glucose Concentrations and of Homeostasis Model Assessment of Insulin Resistance in a Representative Sample of Quebec Children and Adolescents (Pediatric Clinical Chemistry) Distribution of Fasting Plasma Insulin, Free Fatty Acids, And Glucose Concentrations and of Homeostasis Model Assessment of Insulin Resistance in a Representative Sample of Quebec Children and Adolescents (Pediatric Clinical Chemistry)
2003
C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics) C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics)
2001
Acetylcholinesterase Activity and Biogenic Amines in Phenylketonuria (Technical Briefs) Acetylcholinesterase Activity and Biogenic Amines in Phenylketonuria (Technical Briefs)
2002
Homocysteine, 5, 10-Methylenetetrahydrofolate Reductase 677CT Polymorphism, Nutrient Intake, And Incident Cardiovascular Disease in 24 968 Initially Healthy Women (Molecular Diagnostics and Genetics) (Clinical Report) Homocysteine, 5, 10-Methylenetetrahydrofolate Reductase 677CT Polymorphism, Nutrient Intake, And Incident Cardiovascular Disease in 24 968 Initially Healthy Women (Molecular Diagnostics and Genetics) (Clinical Report)
2007