Ascorbic Acid Determination with an Automated Enzymatic Procedure (General Clinical Chemistry) Ascorbic Acid Determination with an Automated Enzymatic Procedure (General Clinical Chemistry)

Ascorbic Acid Determination with an Automated Enzymatic Procedure (General Clinical Chemistry‪)‬

Clinical Chemistry 1997, Jan, 43, 1

    • 2,99 €
    • 2,99 €

Publisher Description

A wide variety of methods involving different chromophores, detection systems, and enzymes has been developed for the determination of ascorbic acid (AA) and dehydroascorbic acid (DHAA) in biological samples. (1) The different principles involved have been reviewed and critiqued by Washko et al. [1]. In recent years HPLC has become the preferred method of determination, but this method has the disadvantages of being relatively labor intensive and costly for a clinical laboratory. In fact, very few currently available AA assays are ideally suited to the clinical laboratory. One such procedure, which is based upon measurement of an enzymatic reaction rate and involves a Beckman Synchron CX5 analyzer, has been previously described by Tulley [2]. Given the increasing interest in nutrition testing, and especially in nutrients that serve as antioxidants such as AA, an automated procedure designed for the clinical laboratory is desirable. To meet this need, we have developed an easily adaptable procedure that has significant advantages over chromatographic and spectrophotometric methods. This enzymatic end point procedure was developed by using the Cobas Fara centrifugal analyzer. In principle, AA is selectively and completely oxidized to DHAA by AA oxidase. The product is then coupled with o-phenylenediamine (OPDA) to yield a chromophore, the absorbance of which is measured at 340 nm.

GENRE
Science & Nature
RELEASED
1997
1 January
LANGUAGE
EN
English
LENGTH
10
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
PROVIDER INFO
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
SIZE
174.7
KB
Alcohol Abuse and Carbohydrate-Deficient Transferrin Analysis: Are Screening and Confirmatory Analysis Required?(Letters) (Letter to the Editor) Alcohol Abuse and Carbohydrate-Deficient Transferrin Analysis: Are Screening and Confirmatory Analysis Required?(Letters) (Letter to the Editor)
2002
Distribution of Adiponectin, Leptin, And Metabolic Correlates of Insulin Resistance: A Longitudinal Study in British Children; 1: Prepuberty (Earlybird 15) (Endocrinology and Metabolism) (Clinical Report) Distribution of Adiponectin, Leptin, And Metabolic Correlates of Insulin Resistance: A Longitudinal Study in British Children; 1: Prepuberty (Earlybird 15) (Endocrinology and Metabolism) (Clinical Report)
2008
Plasminogen Activator Inhibitor 1 4G/5G Polymorphism and Coagulation Factor XIII Val34leu Polymorphism: Impaired Fibrinolysis and Early Pregnancy Loss (Molecular Diagnostics and Genetics) Plasminogen Activator Inhibitor 1 4G/5G Polymorphism and Coagulation Factor XIII Val34leu Polymorphism: Impaired Fibrinolysis and Early Pregnancy Loss (Molecular Diagnostics and Genetics)
2003
Detection of Antinuclear Antibodies by Solid-Phase Immunoassays and Immunofluorescence Analysis (Clinical Immunology) Detection of Antinuclear Antibodies by Solid-Phase Immunoassays and Immunofluorescence Analysis (Clinical Immunology)
2004
Metabolic, Nutritional, Iatrogenic, And Artifactual Sources of Urinary Organic Acids: A Comprehensive Table. Metabolic, Nutritional, Iatrogenic, And Artifactual Sources of Urinary Organic Acids: A Comprehensive Table.
2002
Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial) Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial)
1997