Addition of a Homologous Internal Control to a Real-Time PCR Assay for Detection of Bordetella Pertussis (Technical Briefs) Addition of a Homologous Internal Control to a Real-Time PCR Assay for Detection of Bordetella Pertussis (Technical Briefs)

Addition of a Homologous Internal Control to a Real-Time PCR Assay for Detection of Bordetella Pertussis (Technical Briefs‪)‬

Clinical Chemistry 2005, Dec, 51, 12

    • 5,99 лв.
    • 5,99 лв.

Publisher Description

Pertussis, also called whooping cough, is caused by Bordetella pertussis. The disease may show an atypical course, particularly in neonates and elderly patients. A rapid and safe diagnostic method is thus essential for appropriate treatment and prophylaxis. Culture has been considered the gold standard for detection of B. pertussis, but this method often lacks sensitivity, and a minimum of 4 days may be required to obtain results (1, 2). PCR is a rapid, sensitive, and specific method for the diagnosis of pertussis (3-5). In this study, a new molecular assay was established based on real-time PCR and including a homologous internal control (IC). We evaluated the performance of this assay with a commercially available genomic DNA isolate and with clinical samples.

GENRE
Science & Nature
RELEASED
2005
1 December
LANGUAGE
EN
English
LENGTH
8
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SIZE
230.8
KB

More Books by Clinical Chemistry

D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004
Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs) Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs)
2005
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs) Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs)
2005
Newborn Screening for Lysosomal Storage Disorders (Editorials) Newborn Screening for Lysosomal Storage Disorders (Editorials)
2005
Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor) Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor)
2005