Recoveries of Phenylalanine from Two Sets of Dried-Blood-Spot Reference Materials: Prediction from Hematocrit, Spot Volume, And Paper Matrix (Technical Briefs) Recoveries of Phenylalanine from Two Sets of Dried-Blood-Spot Reference Materials: Prediction from Hematocrit, Spot Volume, And Paper Matrix (Technical Briefs)

Recoveries of Phenylalanine from Two Sets of Dried-Blood-Spot Reference Materials: Prediction from Hematocrit, Spot Volume, And Paper Matrix (Technical Briefs‪)‬

Clinical Chemistry 2000, Jan, 46, 1

    • $5.99
    • $5.99

Publisher Description

Dried blood spots (DBSs) are used to screen newborns for phenylketonuria and other aminoacidopathies. The calibrators for this testing are usually DBSs with values for Phe. Two DBS reference materials have been prepared, the European Working Standard for Phe (EWS-Phe-01) (1) and the amino acid reference material (AARM) from the CDC (2). The two reference materials are not interchangeable because they differ in blood hematocrit, blood-spot size, and filter paper, each of which (3-6) affects analyte recovery. We measured quantitatively the effects of these differences on analyte recovery from DBSs and used results from our measurements to predict expected Phe recoveries from tandem analyses of the two sets of materials. In EWS-Phe-01 (1, 7), human blood with a 50.5% hematocrit and intact red cells was divided into five portions for enrichment with 0, 20, 40, 80, and 120 mg Phe/L blood (0, 120, 240, 480, and 720 [micro]mol/L blood). The liquid added during enrichment (7) was sufficient to reduce the hematocrit to 50.1%. The Phe-enriched blood portions were dispensed in 35-[micro]L aliquots (7) onto Schleicher & Schuell (S&S) Grade 2992 (lot no. 121576) filter paper (1).

GENRE
Science & Nature
RELEASED
2000
January 1
LANGUAGE
EN
English
LENGTH
9
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SELLER
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
SIZE
199.5
KB

More Books Like This

Capillary Isoelectric Focusing and High-Performance Cation-Exchange Chromatography Compared for Qualitative and Quantitative Analysis of Hemoglobin Variants (Automation and Analytical Techniques) Capillary Isoelectric Focusing and High-Performance Cation-Exchange Chromatography Compared for Qualitative and Quantitative Analysis of Hemoglobin Variants (Automation and Analytical Techniques)
1997
Can Whole-Blood Samples Be Stored over 24 Hours Without Compromising Stability of C-Reactive Protein, Retinol, Ferritin, Folic Acid, And Fatty Acids in Epidemiologic Research?(Technical Briefs) (Clinical Report) Can Whole-Blood Samples Be Stored over 24 Hours Without Compromising Stability of C-Reactive Protein, Retinol, Ferritin, Folic Acid, And Fatty Acids in Epidemiologic Research?(Technical Briefs) (Clinical Report)
2005
Interlaboratory Variation of Plasma Total Homocysteine Measurements: Results of Three Successive Homocysteine Proficiency Testing Surveys (General Clinical Chemistry) Interlaboratory Variation of Plasma Total Homocysteine Measurements: Results of Three Successive Homocysteine Proficiency Testing Surveys (General Clinical Chemistry)
2002
Principles and Applications of Clinical Mass Spectrometry Principles and Applications of Clinical Mass Spectrometry
2018
Serial Assessment of Biochemical Parameters of Red Cell Preparations to Evaluate Safety for Neonatal Transfusions (Report) Serial Assessment of Biochemical Parameters of Red Cell Preparations to Evaluate Safety for Neonatal Transfusions (Report)
2010
Fundamentals of Analytical Toxicology Fundamentals of Analytical Toxicology
2020

More Books by Clinical Chemistry

Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial) Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial)
1997
Vitamin E and Coronary Heart Disease in Tunisians (Nutrition) (Clinical Report) Vitamin E and Coronary Heart Disease in Tunisians (Nutrition) (Clinical Report)
2000
Endothelial Nitric Oxide Synthase Haplotypes Are Associated with Features of Metabolic Syndrome (Endocrinology and Metabolism) (Survey) Endothelial Nitric Oxide Synthase Haplotypes Are Associated with Features of Metabolic Syndrome (Endocrinology and Metabolism) (Survey)
2007
T-Cell Regulatory Gene CTLA-4 Polymorphism/Haplotype Association with Autoimmune Pancreatitis (Clinical Immunology) T-Cell Regulatory Gene CTLA-4 Polymorphism/Haplotype Association with Autoimmune Pancreatitis (Clinical Immunology)
2007
Percent Free Prostate-Specific Antigen in Assessing the Probability of Prostate Cancer Under Optimal Analytical Conditions (Enzymes and Protein Markers) Percent Free Prostate-Specific Antigen in Assessing the Probability of Prostate Cancer Under Optimal Analytical Conditions (Enzymes and Protein Markers)
1998
High-Throughput Genotyping of Oncogenic Human Papilloma Viruses with MALDI-TOF Mass Spectrometry (Molecular Diagnostics and Genetics) High-Throughput Genotyping of Oncogenic Human Papilloma Viruses with MALDI-TOF Mass Spectrometry (Molecular Diagnostics and Genetics)
2008