Fluorescence Single-Molecule Counting Assays for High-Sensitivity Detection of Cytokines and Chemokines (Abstracts of Oak Ridge Posters) Fluorescence Single-Molecule Counting Assays for High-Sensitivity Detection of Cytokines and Chemokines (Abstracts of Oak Ridge Posters)

Fluorescence Single-Molecule Counting Assays for High-Sensitivity Detection of Cytokines and Chemokines (Abstracts of Oak Ridge Posters‪)‬

Clinical Chemistry 2007, Nov, 53, 11

    • CHF 3.00
    • CHF 3.00

Publisher Description

A recent focus in clinical immunodiagnostics is to improve sensitivity of assays for rare circulating protein biomarkers. The ability to detect low concentrations of certain biomarkers translates to diagnosis of disease at an earlier stage, which can positively impact prognosis and disease management (1-3). In research (for example in the discovery and development of new biomarkers), targeted assays for individual proteins are often required before multiplexing strategies are developed. Cross-reactivity of antibodies often compromises assay sensitivity in multiplexed immunoassays (4). Ultrasensitive individual assays consume only small sample volumes, a characteristic that can be advantageous in the case of scarce archival clinical samples. The development of single-molecule detection approaches has provided new opportunities for improving immunoassay sensitivity and miniaturization (5). Fluorescence confocal microscopy with laser-induced excitation enables single-molecule detection in extremely small interrogation zones (on the order of femtoliters). By reducing interrogation zones to these dimensions and carefully tuning the timescales of the data acquisition and molecular flow rates, background interference is decreased and individual molecules are readily recorded as discrete fluorescence bursts above background (6). Counting these bursts, or molecular events, by applying fluorescence thresholds on the basis of the internally derived background noise generates experimental data whose precision is dictated by counting statistics. Hence, sample read times can be adjusted to achieve a desired counting precision. The combination of small interrogation volumes and short sample read times can also lead to rapid analysis.

GENRE
Science & Nature
RELEASED
2007
1 November
LANGUAGE
EN
English
LENGTH
10
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SIZE
196.9
KB

More Books by Clinical Chemistry

The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments (Special Report) (Polymerase Chain Reaction) (Report) The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments (Special Report) (Polymerase Chain Reaction) (Report)
2009
D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004
Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs) Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs)
2005
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs) Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs)
2005
Newborn Screening for Lysosomal Storage Disorders (Editorials) Newborn Screening for Lysosomal Storage Disorders (Editorials)