Another Step Toward Standardization of Methods for Measuring Hemoglobin [a.Sub.1C] (Editorial) Another Step Toward Standardization of Methods for Measuring Hemoglobin [a.Sub.1C] (Editorial)

Another Step Toward Standardization of Methods for Measuring Hemoglobin [a.Sub.1C] (Editorial‪)‬

Clinical Chemistry 1997, Oct, 43, 10

    • 2,99 €
    • 2,99 €

Beschreibung des Verlags

In this issue, Kobold et al. describe an exciting new Reference Method for hemoglobin [A.sub.1c], developed by the International Federation of Clinical Chemistry Working Group on Hemoglobin [A.sub.1c], [1]. To our knowledge, this method represents the first time mass spectrometry has been applied to a protein of clinical interest in a high-level (Definitive) Reference Method. Measurements of hemoglobin [A.sub.1c] (or, alternatively, of glycohemoglobin) are increasingly important in the monitoring of glucose control in patients with diabetes. The test's importance became especially prominent after the publication of the Diabetes Control and Complications Trial (DCCT), which demonstrated the importance of control of blood glucose in the prevention or delay of the complications of diabetes [2]. The test has recently caught the eye of the US government as one that is underutilized [3]. Thus, it is not much surprise that both an AACC Subcommittee, which has evolved into the National Glycohemoglobin Standardization Program (NGSP) [4], and an IFCC Working Group, from which Kobold's report emanates, have been addressing glycohemoglobin standardization over the past several years. Several other editorials in this journal [5-7] have commented on important papers relating to glycohemoglobin over the years. Because the most recent of these, one by Miedema, gave such a good overview of the chemistry of glucose addition to hemoglobin, nomenclature, and analytical methodologies, we will not repeat this information here. Instead, our discussion will focus on the relative importance of accurate results, harmonious results, and the preservation of reference values with which clinicians are familiar.

GENRE
Wissenschaft und Natur
ERSCHIENEN
1997
1. Oktober
SPRACHE
EN
Englisch
UMFANG
8
Seiten
VERLAG
American Association for Clinical Chemistry, Inc.
ANBIETERINFO
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
GRÖSSE
172,3
 kB
Electrospray Mass Spectrometry for Measurement of Glycohemoglobin (Editorial) (Clinical Report) Electrospray Mass Spectrometry for Measurement of Glycohemoglobin (Editorial) (Clinical Report)
1997
Components of Total Measurement Error for Hemoglobin [A.Sub.1C] (Technical Briefs) (Clinical Report) Components of Total Measurement Error for Hemoglobin [A.Sub.1C] (Technical Briefs) (Clinical Report)
2001
Hemoglobin Variants and Hemoglobin [a.Sub.1C] Analysis: Problem Solved?(Editorial) Hemoglobin Variants and Hemoglobin [a.Sub.1C] Analysis: Problem Solved?(Editorial)
2003
Therapeutic Delivery Solutions Therapeutic Delivery Solutions
2014
Metabolomics in Practice Metabolomics in Practice
2013
Molecular Epidemiology of Chronic Diseases Molecular Epidemiology of Chronic Diseases
2011
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Longitudinal Concentrations of Vitamin [B.Sub.12] and Vitamin [B.Sub.12]-Binding Proteins During Uncomplicated Pregnancy (General Clinical Chemistry) (Clinical Report) Longitudinal Concentrations of Vitamin [B.Sub.12] and Vitamin [B.Sub.12]-Binding Proteins During Uncomplicated Pregnancy (General Clinical Chemistry) (Clinical Report)
2002
Multicenter Characterization and Validation of the Intron-8 Poly(T) Tract (IVS8-T) Status in 25 Coriell Cell Repository Cystic Fibrosis Reference Cell Lines for Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) Gene Mutation Assays (Technical Briefs) Multicenter Characterization and Validation of the Intron-8 Poly(T) Tract (IVS8-T) Status in 25 Coriell Cell Repository Cystic Fibrosis Reference Cell Lines for Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) Gene Mutation Assays (Technical Briefs)
2004
Immunoassay Standardization: Is It Possible, Who Is Responsible, Who Is Capable?(Opinion) (Clinical Report) Immunoassay Standardization: Is It Possible, Who Is Responsible, Who Is Capable?(Opinion) (Clinical Report)
2001
A Conversation with Elizabeth Blackburn (Interview) A Conversation with Elizabeth Blackburn (Interview)
2009
The Evolution of Immunoassay As Seen Through the Journal Clinical Chemistry (Aacc 50th Years Anniversary Retrospective) The Evolution of Immunoassay As Seen Through the Journal Clinical Chemistry (Aacc 50th Years Anniversary Retrospective)
1998