D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)

D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report‪)‬

Clinical Chemistry 2004, July, 50, 7

    • 2,99 €
    • 2,99 €

Beschreibung des Verlags

Deep venous thrombosis (DVT) (4) is a common condition with significant morbidity and mortality if not diagnosed and treated in a timely manner. The clinical signs and symptoms of DVT are nonspecific, and objective testing is required for diagnosis. Diagnostic imaging with contrast venography or compression ultrasonography has important limitations. Venography is invasive and expensive, is contraindicated in some patients, and requires a radiologist to perform. Compression ultrasound also requires a radiologist's interpretation and has poor sensitivity for detection of calf vein thrombosis, and serial testing is often required when the initial scan is negative. The measurement of D-dimer, degradation products of circulating cross-linked fibrin formed during activation of the coagulation system, has been studied extensively as an adjuvant test in the diagnosis of DVT. D-Dimer testing has become rapid, simple, and inexpensive, and it has the potential to detect thrombosis in any part of the venous system. If the sensitivity of the D-dimer test for DVT is consistently very high, its negative predictive value will also be high and reliably exclude the presence of disease. These are characteristics of a good "rule-out" test. As such, the use of D-dimer assays has been suggested as an initial test to rule out DVT to reduce the number of patients requiring diagnostic imaging. In 1996, our systematic review did not find sufficient evidence to support the use of D-dimer as a diagnostic test for DVT (1). However, since that time several new D-dimer assays have been introduced, and 50 studies and 8 reviews on the subject have been published (2-9). Because none of the reviews critically appraised the primary studies or discussed the potential for bias in their results, we undertook this metaanalysis of the D-dimer accuracy literature published since our last systematic review to clarify the role of the test in the diagnosis of lower extremity DVT.

GENRE
Wissenschaft und Natur
ERSCHIENEN
2004
1. Juli
SPRACHE
EN
Englisch
UMFANG
40
Seiten
VERLAG
American Association for Clinical Chemistry, Inc.
ANBIETERINFO
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
GRÖSSE
232,8
 kB
The D-Dimer Test for Deep Venous Thrombosis: Gold Standards and Bias in Negative Predictive Value (Evidence-Based Laboratory Medicine and Test Utilization) The D-Dimer Test for Deep Venous Thrombosis: Gold Standards and Bias in Negative Predictive Value (Evidence-Based Laboratory Medicine and Test Utilization)
2003
Frequency of Thrombophilia-Related Genetic Variations in Patients with Idiopathic Pulmonary Embolism in an Urban Emergency Department (Molecular Diagnostics and Genetics) (Clinical Report) Frequency of Thrombophilia-Related Genetic Variations in Patients with Idiopathic Pulmonary Embolism in an Urban Emergency Department (Molecular Diagnostics and Genetics) (Clinical Report)
2006
Test Research Versus Diagnostic Research (Opinion) Test Research Versus Diagnostic Research (Opinion)
2004
A Prospective Study of Risk Factor Profile & Incidence of Deep Venous Thrombosis Among Medically-Ill Hospitalized Patients at a Tertiary Care Hospital in Northern India (Report) A Prospective Study of Risk Factor Profile & Incidence of Deep Venous Thrombosis Among Medically-Ill Hospitalized Patients at a Tertiary Care Hospital in Northern India (Report)
2009
Large-Scale Observational Studies of Hypericum Extracts in Patients with Depressive Disorders--a Systematic Review. Large-Scale Observational Studies of Hypericum Extracts in Patients with Depressive Disorders--a Systematic Review.
2005
Statistical Issues in Drug Research and Development Statistical Issues in Drug Research and Development
2017
Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs) Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs)
2005
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs) Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs)
2005
Newborn Screening for Lysosomal Storage Disorders (Editorials) Newborn Screening for Lysosomal Storage Disorders (Editorials)
2005
Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor) Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor)
2005
Effects of Preanalytical Factors on the Molecular Size of Cell-Free DNA in Blood (Technical Briefs) Effects of Preanalytical Factors on the Molecular Size of Cell-Free DNA in Blood (Technical Briefs)
2005