Evaluation of DNA Fragment Sizing and Quantification by the Agilent 2100 Bioanalyzer (Technical Briefs) Evaluation of DNA Fragment Sizing and Quantification by the Agilent 2100 Bioanalyzer (Technical Briefs)

Evaluation of DNA Fragment Sizing and Quantification by the Agilent 2100 Bioanalyzer (Technical Briefs‪)‬

Clinical Chemistry 2000, Nov, 46, 11

    • 2,99 €
    • 2,99 €

Beschreibung des Verlags

Capillary electrophoresis (CE) achieves efficient separation of molecular species by the application of high voltages to samples in solution (1). Commercial CE units, available for slightly more than a decade, have found numerous applications (2-6), but are expensive (;$60 000) and require substantial user training and experience. Recent advances have allowed CE to be performed on microchip devices (7-11 ). We evaluated the Agilent 2100 Bioanalyzer (Agilent Technologies), which represents a new generation of CE instruments that use this technology. The Bioanalyzer is relatively inexpensive (~$18 000) and is simple to operate, requiring only routine pipetting and basic computer skills. Typically, 12 nucleic acid samples can be sized and quantified on a disposable chip within 30 min. Chips are fabricated from glass and comprise an interconnected network of fluid reservoirs and microchannels, which must be filled with a gel-dye mixture. Each chip contains 16 wells: 3 for loading the gel-dye mixture, 1 for a molecular size ladder, and 12 for experimental samples. The movement of nucleic acids through the microchannels is controlled by a series of electrodes, each of which is independently connected to a common power supply. The Bioanalyzer displays data as both migration-time plots and as computer-generated virtual gels. Traditional CE operating variables [temperature, voltage, capillary material, and pH, ionic strength, and viscosity of buffer (12)] cannot be modified. The instruments costs ~$18 000, and chips cost ~$12-18 per chip ($1-1.50 per sample).

GENRE
Wissenschaft und Natur
ERSCHIENEN
2000
1. November
SPRACHE
EN
Englisch
UMFANG
11
Seiten
VERLAG
American Association for Clinical Chemistry, Inc.
ANBIETERINFO
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
GRÖSSE
181,7
 kB
Improvement of Low-Density Microelectronic Array Technology to Characterize 14 Mutations/Single-Nucleotide Polymorphisms from Several Human Genes on a Large Scale (Technical Briefs) Improvement of Low-Density Microelectronic Array Technology to Characterize 14 Mutations/Single-Nucleotide Polymorphisms from Several Human Genes on a Large Scale (Technical Briefs)
2004
Fully Automated, Homogeneous Nucleic Acid Detection Technology Based on Dry-Reagent Assay Chemistry and Time-Resolved Fluorometry (Abstracts of Oak Ridge Posters) Fully Automated, Homogeneous Nucleic Acid Detection Technology Based on Dry-Reagent Assay Chemistry and Time-Resolved Fluorometry (Abstracts of Oak Ridge Posters)
2007
Molecular Analysis and Genome Discovery Molecular Analysis and Genome Discovery
2011
Bioanalytical Chemistry Bioanalytical Chemistry
2016
Detection of Biological Threat Agents by Real-Time PCR: Comparison of Assay Performance on the R.A.P.I.D., the Lightcycler, And the Smart Cycler Platforms (Technical Briefs) Detection of Biological Threat Agents by Real-Time PCR: Comparison of Assay Performance on the R.A.P.I.D., the Lightcycler, And the Smart Cycler Platforms (Technical Briefs)
2006
Separation Techniques Applied to Omics Sciences Separation Techniques Applied to Omics Sciences
2021
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Longitudinal Concentrations of Vitamin [B.Sub.12] and Vitamin [B.Sub.12]-Binding Proteins During Uncomplicated Pregnancy (General Clinical Chemistry) (Clinical Report) Longitudinal Concentrations of Vitamin [B.Sub.12] and Vitamin [B.Sub.12]-Binding Proteins During Uncomplicated Pregnancy (General Clinical Chemistry) (Clinical Report)
2002
Multicenter Characterization and Validation of the Intron-8 Poly(T) Tract (IVS8-T) Status in 25 Coriell Cell Repository Cystic Fibrosis Reference Cell Lines for Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) Gene Mutation Assays (Technical Briefs) Multicenter Characterization and Validation of the Intron-8 Poly(T) Tract (IVS8-T) Status in 25 Coriell Cell Repository Cystic Fibrosis Reference Cell Lines for Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) Gene Mutation Assays (Technical Briefs)
2004
Immunoassay Standardization: Is It Possible, Who Is Responsible, Who Is Capable?(Opinion) (Clinical Report) Immunoassay Standardization: Is It Possible, Who Is Responsible, Who Is Capable?(Opinion) (Clinical Report)
2001
A Conversation with Elizabeth Blackburn (Interview) A Conversation with Elizabeth Blackburn (Interview)
2009
The Evolution of Immunoassay As Seen Through the Journal Clinical Chemistry (Aacc 50th Years Anniversary Retrospective) The Evolution of Immunoassay As Seen Through the Journal Clinical Chemistry (Aacc 50th Years Anniversary Retrospective)
1998