Microalbuminuria, defined as a urinary albumin concentration (UAC) of 20-200 mg/L, is an early predictor of diabetic nephropathy (1-6). In addition, microalbuminuria is a marker of cardiovascular morbidity and mortality, both in patients with diabetes mellitus and in the general population (7-17). Consequently, there is great interest in screening for microalbuminuria in these groups. In cohort studies, urine samples are often kept frozen at -20[degrees]C before analysis. Although some study results have indicated no effect of freezing on UAC (18-23), other studies have found erroneously low values when samples were frozen at -20 [degrees]C (24-27). Only a few studies have investigated the effect of longer storage periods, but these studies were small, and samples were in the macroalbuminuric range (200 mg/L). We investigated the effects of storage at -20 [degrees]C for up to 24 months, mixing methods, and baseline UAC on samples in the normo- and microalbuminuric ranges. Urine samples were collected during the prospective PREVEND study in the general population initiated to investigate urinary albumin excretion as a predictor of renal and cardiovascular disease (28). The participants were asked to collect urine for two 24-h periods and to store it in two 3-L plastic containers at 7 [degrees]C and deliver it within 2 days to the clinic. Immediately after delivery, the urine sample volume was determined, and a portion of each of the 24-h samples was stored in 2-mL polypropylene aliquots at -20 [degrees]C for albumin assessment after freezing. For measurement of UAC in fresh samples, portions were kept at 7[degrees]C in 10-mL polystyrene tubes until the UAC was measured.

GENRE
Wissenschaft und Natur
ERSCHIENEN
2005
1. November
SPRACHE
EN
Englisch
UMFANG
11
Seiten
VERLAG
American Association for Clinical Chemistry, Inc.
GRÖSSE
182,5
 kB

Mehr ähnliche Bücher

[[Alpha].Sub.1]-Microglobulin Is Stable in Human Urine Ex Vivo (Letters) (Letter to the Editor) [[Alpha].Sub.1]-Microglobulin Is Stable in Human Urine Ex Vivo (Letters) (Letter to the Editor)
2002
Urinary Measurement of Transforming Growth Factor-[Beta] and Type Iv Collagen As New Markers of Renal Injury: Application in Diabetic Nephropathy (Enzymes and Protein Markers) Urinary Measurement of Transforming Growth Factor-[Beta] and Type Iv Collagen As New Markers of Renal Injury: Application in Diabetic Nephropathy (Enzymes and Protein Markers)
1998
Urinary Glycosaminoglycan Excretion in Newly Diagnosed Essential Hypertensive Patients (Technical Briefs) (Clinical Report) Urinary Glycosaminoglycan Excretion in Newly Diagnosed Essential Hypertensive Patients (Technical Briefs) (Clinical Report)
2000
Contemporary Practice in Clinical Chemistry (Enhanced Edition) Contemporary Practice in Clinical Chemistry (Enhanced Edition)
2020
Kidney Biomarkers (Enhanced Edition) Kidney Biomarkers (Enhanced Edition)
2020
Selective Precipitation Based Economical Methods for Purification of Human Serum Albumin from the Out-Dated Blood Bank Samples (Report) Selective Precipitation Based Economical Methods for Purification of Human Serum Albumin from the Out-Dated Blood Bank Samples (Report)
2010

Mehr Bücher von Clinical Chemistry

Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Longitudinal Concentrations of Vitamin [B.Sub.12] and Vitamin [B.Sub.12]-Binding Proteins During Uncomplicated Pregnancy (General Clinical Chemistry) (Clinical Report) Longitudinal Concentrations of Vitamin [B.Sub.12] and Vitamin [B.Sub.12]-Binding Proteins During Uncomplicated Pregnancy (General Clinical Chemistry) (Clinical Report)
2002
Multicenter Characterization and Validation of the Intron-8 Poly(T) Tract (IVS8-T) Status in 25 Coriell Cell Repository Cystic Fibrosis Reference Cell Lines for Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) Gene Mutation Assays (Technical Briefs) Multicenter Characterization and Validation of the Intron-8 Poly(T) Tract (IVS8-T) Status in 25 Coriell Cell Repository Cystic Fibrosis Reference Cell Lines for Cystic Fibrosis Transmembrane Conductance Regulator (CFTR) Gene Mutation Assays (Technical Briefs)
2004
Immunoassay Standardization: Is It Possible, Who Is Responsible, Who Is Capable?(Opinion) (Clinical Report) Immunoassay Standardization: Is It Possible, Who Is Responsible, Who Is Capable?(Opinion) (Clinical Report)
2001
A Conversation with Elizabeth Blackburn (Interview) A Conversation with Elizabeth Blackburn (Interview)
2009
The Evolution of Immunoassay As Seen Through the Journal Clinical Chemistry (Aacc 50th Years Anniversary Retrospective) The Evolution of Immunoassay As Seen Through the Journal Clinical Chemistry (Aacc 50th Years Anniversary Retrospective)
1998