A Stochastic Approximation Method for Assigning Values to Calibrators (Laboratory Management) A Stochastic Approximation Method for Assigning Values to Calibrators (Laboratory Management)

A Stochastic Approximation Method for Assigning Values to Calibrators (Laboratory Management‪)‬

Clinical Chemistry 1998, April, 44, 4

    • 2,99 €
    • 2,99 €

Descripción editorial

The problem of transferring the analyte concentration value of a reference material to a new production calibrator is a common manufacturing activity in the in vitro medical diagnostic industry. Many popular approaches to this problem, whether they use consensus values from many laboratories, reference laboratories, or master lots, involve fitting calibration curves to assay responses of reference standards to determine the concentration values of the new production calibrators, which are assayed as unknowns (1, 2). There are at least two potential problems with this approach: Any consistent systematic error in fitting the calibration curve is propagated to the value assignment of the production calibrator regardless of how many assay setups (or runs) are used, and the required sample sizes, even with a single instrument, are direct functions of the magnitudes of the random variabilities of fitted calibration curves and/or assay setups together with the within-run variabilities. With consensus value methods, the required sample sizes are further increased by the variabilities among laboratories, analyzers, and assay methods. The object of this paper is to provide a simpler, more economical method of value assignment that is robust to calibration curve-fitting errors and has its required sample size driven only by the smallest component of variability, which is the intraassay signal response SD, rather than by the interassay or interlaboratory sources of variabilities of recovered values, which drive up sample sizes. For the case in which both the production calibrators and the reference materials have the same signal-response curve, which is linear in analyte concentration with a zero intercept, this problem has already been solved by the following well known equation (1):

GÉNERO
Ciencia y naturaleza
PUBLICADO
1998
1 de abril
IDIOMA
EN
Inglés
EXTENSIÓN
32
Páginas
EDITORIAL
American Association for Clinical Chemistry, Inc.
INFORMACIÓN DEL PROVEEDOR
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
TAMAÑO
214,4
KB
Celiac Disease and IGA Deficiency: Complications of Serological Testing Approaches Encountered in the Clinic (Evidence-Based Laboratory Medicine and Test Utilization) (Clinical Report) Celiac Disease and IGA Deficiency: Complications of Serological Testing Approaches Encountered in the Clinic (Evidence-Based Laboratory Medicine and Test Utilization) (Clinical Report)
2008
None of Four Commercially Available Assays Detects Prolactin in Human Saliva (Technical Briefs) None of Four Commercially Available Assays Detects Prolactin in Human Saliva (Technical Briefs)
2000
D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004
Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs) Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs)
2005
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs) Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs)
2005