Improvement of Low-Density Microelectronic Array Technology to Characterize 14 Mutations/Single-Nucleotide Polymorphisms from Several Human Genes on a Large Scale (Technical Briefs) Improvement of Low-Density Microelectronic Array Technology to Characterize 14 Mutations/Single-Nucleotide Polymorphisms from Several Human Genes on a Large Scale (Technical Briefs)

Improvement of Low-Density Microelectronic Array Technology to Characterize 14 Mutations/Single-Nucleotide Polymorphisms from Several Human Genes on a Large Scale (Technical Briefs‪)‬

Clinical Chemistry 2004, April, 50, 4

    • 2,99 €
    • 2,99 €

Descripción editorial

Large-scale human genetic studies require new technologies to genotype several samples with relative ease, high accuracy, and reasonable costs. Among the available approaches, a microelectronic array technology has been developed for DNA hybridization analysis of mutations/ single-nucleotide polymorphisms (SNPs) (1-4). The microelectronic array system (NanoChip[R] Molecular Biology Workstation; Nanogen) produces a defined electric field that allows charged molecules, such as nucleic acids, to be transported to any test site, or pad, on the electronic chip (NanoChip cartridge). Electronic-based molecule addressing can rapidly achieve a high concentration of amplicons on each pad of the cartridge. Control of temperature allows use of an optimal thermal stringency to characterize a SNP/mutation in all 100 pads of a cartridge simultaneously (5, 6). A thin hydrogel permeation layer overlies the pads; the presence of avidin or streptavidin in this layer allows the binding of biotinylated PCR products. Although the technology is attractive, only a few protocols for its use have been published (7-11). We describe the development, optimization, and validation of a high-throughput method for SNPs and mutations analysis that allows performance of 1372 characterizations on each chip.

GÉNERO
Ciencia y naturaleza
PUBLICADO
2004
1 de abril
IDIOMA
EN
Inglés
EXTENSIÓN
8
Páginas
EDITORIAL
American Association for Clinical Chemistry, Inc.
INFORMACIÓN DEL PROVEEDOR
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
TAMAÑO
208,2
KB
Celiac Disease and IGA Deficiency: Complications of Serological Testing Approaches Encountered in the Clinic (Evidence-Based Laboratory Medicine and Test Utilization) (Clinical Report) Celiac Disease and IGA Deficiency: Complications of Serological Testing Approaches Encountered in the Clinic (Evidence-Based Laboratory Medicine and Test Utilization) (Clinical Report)
2008
None of Four Commercially Available Assays Detects Prolactin in Human Saliva (Technical Briefs) None of Four Commercially Available Assays Detects Prolactin in Human Saliva (Technical Briefs)
2000
D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004
Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs) Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs)
2005
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs) Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs)
2005