Two Cases with Unusual Vancomycin Measurements (Clinical Case Study) (Case Study) Two Cases with Unusual Vancomycin Measurements (Clinical Case Study) (Case Study)

Two Cases with Unusual Vancomycin Measurements (Clinical Case Study) (Case Study‪)‬

Clinical Chemistry 2009, March, 55, 3

    • €2.99
    • €2.99

Publisher Description

CASE Patient A was a 68-year-old woman with a history of lymphoplasmacytic lymphoma who presented after several weeks of mucosal bleeding. On admission, her cancer involved 95% of bone marrow cells. She was pancytopenic and febrile (38.3 [degrees]C). Leukocyte count was 0.39 x [10.sup.3]/[micro]L (neutrophils, 0.03 x [10.sup.3]/ AL), hematocrit 25%, platelet count 21 x [10.sup.3]/[micro]L, relative serum viscosity 2.3 (reference interval, 1.4-1.8), blood urea nitrogen 6.4 mmol/L (18 mg/dL), creatinine 62 [micro]mol/L (0.7 mg/dQ, and estimated glomerular filtration rate 60 mL/min/1.73 [m.sup.2]. She had an IgM[KAPPA] monoclonal component of 42.8 g/L. This patient was started on vancomycin 1 g intravenously (IV) every 12 h, ceftazidime 2 g IV every 8 h, and a course of chemotherapy. On day 3 after the beginning of antibiotic treatment, a trough specimen was collected for measurement of vancomycin. The concentration, measured with a Beckman Coulter Synchron competitive turbidimetric immunoassay, was 0.1 mg/L. The result, which was incompatible with ongoing vancomycin therapy, signaled a problem to the technologist. No analytical issues were evident upon review of calibration, controls, and results for other chemistry tests performed on the same specimen. In an attempt to resolve an apparent falsely low result, a 1:1 mix of the specimen was made with the Beckman liquid comprehensive control serum (level 3, 30.4 mg/L) and demonstrated near complete recovery (result of mix after adjusting for dilution, 28.6 mg/L). However, a 1:1 mix with pooled patient serum containing vancomycin (11 mg/L) led to only 15% recovery (result of mix after adjustment for dilution, 1.7 mg/L). The specimen was subsequently sent to another laboratory, where a vancomycin concentration of 9.8 mg/L was measured by use of a competitive enzyme-finked immunoassay (Emit, Olympus).

GENRE
Science & Nature
RELEASED
2009
1 March
LANGUAGE
EN
English
LENGTH
13
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SIZE
177.8
KB

More Books Like This

Biotin and Other Interferences in Immunoassays (Enhanced Edition) Biotin and Other Interferences in Immunoassays (Enhanced Edition)
2019
Dilution Protocols for Detection of Hook Effects/Prozone Phenomenon (Letters) (Letter to the Editor) Dilution Protocols for Detection of Hook Effects/Prozone Phenomenon (Letters) (Letter to the Editor)
2000
Contemporary Practice in Clinical Chemistry (Enhanced Edition) Contemporary Practice in Clinical Chemistry (Enhanced Edition)
2020
Misleading High Thyrotropin Results Obtained with a Two-Site Immunometric Assay Involving a Chimeric Antibody (Technical Briefs) Misleading High Thyrotropin Results Obtained with a Two-Site Immunometric Assay Involving a Chimeric Antibody (Technical Briefs)
2004
Prevalence of Heterophilic Antibody Interference in Eight Automated Tumor Marker Immunoassays (Technical Briefs) Prevalence of Heterophilic Antibody Interference in Eight Automated Tumor Marker Immunoassays (Technical Briefs)
2005
Bioanalytical Aspects in Biological Therapeutics Bioanalytical Aspects in Biological Therapeutics
2022

More Books by Clinical Chemistry

Impact of the Third Cholesterol Report from the Adult Treatment Panel of the National Cholesterol Education Program on the Clinical Laboratory (Special Report) Impact of the Third Cholesterol Report from the Adult Treatment Panel of the National Cholesterol Education Program on the Clinical Laboratory (Special Report)
2002
DNA Methylation Changes in Sera of Women in Early Pregnancy are Similar to Those in Advanced Breast Cancer Patients (Technical Briefs) DNA Methylation Changes in Sera of Women in Early Pregnancy are Similar to Those in Advanced Breast Cancer Patients (Technical Briefs)
2004
Colorectal Carcinoma Susceptibility and Metastases are Associated with Matrix Metalloproteinase-7 Promoter Polymorphisms (Technical Briefs) Colorectal Carcinoma Susceptibility and Metastases are Associated with Matrix Metalloproteinase-7 Promoter Polymorphisms (Technical Briefs)
2003
High-Sensitivity C-Reactive Protein As a Predictor of All-Cause Mortality: Implications for Research and Patient Care (Editorial) High-Sensitivity C-Reactive Protein As a Predictor of All-Cause Mortality: Implications for Research and Patient Care (Editorial)
2008
Biological Variation of Tumor Markers and Its Application in the Detection of Disease Progression in Patients with Non-Small Cell Lung Cancer (Technical Briefs) Biological Variation of Tumor Markers and Its Application in the Detection of Disease Progression in Patients with Non-Small Cell Lung Cancer (Technical Briefs)
2005
D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004