[[Alpha].Sub.1]-Microglobulin Is Stable in Human Urine Ex Vivo (Letters) (Letter to the Editor) [[Alpha].Sub.1]-Microglobulin Is Stable in Human Urine Ex Vivo (Letters) (Letter to the Editor)

[[Alpha].Sub.1]-Microglobulin Is Stable in Human Urine Ex Vivo (Letters) (Letter to the Editor‪)‬

Clinical Chemistry 2002, July, 48, 7

    • 2,99 €
    • 2,99 €

Descrizione dell’editore

To the Editor: Increased concentrations of urinary [[alpha].sub.1]-microglobulin may imply proximal tubular damage (1). [[alpha].sub.1]-Microglobulin has generally been considered to be stable in human urine (1, 2). Tencer et al. (2) observed good stability in 10 urine samples stored at room temperature for 7 days, at 4 [degrees]C for 30 days, and at -20 [degrees]C for 6 months. In contrast, Donaldson et al. (3) noted significant losses of [[alpha].sub.1]-microglobulin in urine stored at -20 [degrees]C and that this problem was exacerbated in more acidic (pH 6.0) urines; they recommend that urine should be neutralized on receipt. The manufacturers of our assay recommend that urines be assayed fresh or stored at 4 [degrees]C for a period of less than 1 week and warn against freezing samples. Urine samples are often stored before batch analysis. To clarify the appropriate storage conditions for urinary [[alpha].sub.1]-microglobulin, we studied stability under standardized conditions.

GENERE
Scienza e natura
PUBBLICATO
2002
1 luglio
LINGUA
EN
Inglese
PAGINE
9
EDITORE
American Association for Clinical Chemistry, Inc.
DIMENSIONE
163,5
KB

Altri libri di Clinical Chemistry

Alcohol Abuse and Carbohydrate-Deficient Transferrin Analysis: Are Screening and Confirmatory Analysis Required?(Letters) (Letter to the Editor) Alcohol Abuse and Carbohydrate-Deficient Transferrin Analysis: Are Screening and Confirmatory Analysis Required?(Letters) (Letter to the Editor)
2002
Biological Variation of Vitamins in Blood of Healthy Individuals (Nutrition) Biological Variation of Vitamins in Blood of Healthy Individuals (Nutrition)
2005
Reproducibility of Blood Markers of Oxidative Status and Endothelial Function in Healthy Individuals (Technical Briefs) Reproducibility of Blood Markers of Oxidative Status and Endothelial Function in Healthy Individuals (Technical Briefs)
2003
Homocysteine and Folate Status in an Era of Folic Acid Fortification: Balancing Benefits, Risks, And B-Vitamins (Editorial) Homocysteine and Folate Status in an Era of Folic Acid Fortification: Balancing Benefits, Risks, And B-Vitamins (Editorial)
2008
Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs) Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs)
2005
D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004