Two Cases with Unusual Vancomycin Measurements (Clinical Case Study) (Case Study) Two Cases with Unusual Vancomycin Measurements (Clinical Case Study) (Case Study)

Two Cases with Unusual Vancomycin Measurements (Clinical Case Study) (Case Study‪)‬

Clinical Chemistry 2009, March, 55, 3

    • 2,99 €
    • 2,99 €

Descrizione dell’editore

CASE Patient A was a 68-year-old woman with a history of lymphoplasmacytic lymphoma who presented after several weeks of mucosal bleeding. On admission, her cancer involved 95% of bone marrow cells. She was pancytopenic and febrile (38.3 [degrees]C). Leukocyte count was 0.39 x [10.sup.3]/[micro]L (neutrophils, 0.03 x [10.sup.3]/ AL), hematocrit 25%, platelet count 21 x [10.sup.3]/[micro]L, relative serum viscosity 2.3 (reference interval, 1.4-1.8), blood urea nitrogen 6.4 mmol/L (18 mg/dL), creatinine 62 [micro]mol/L (0.7 mg/dQ, and estimated glomerular filtration rate 60 mL/min/1.73 [m.sup.2]. She had an IgM[KAPPA] monoclonal component of 42.8 g/L. This patient was started on vancomycin 1 g intravenously (IV) every 12 h, ceftazidime 2 g IV every 8 h, and a course of chemotherapy. On day 3 after the beginning of antibiotic treatment, a trough specimen was collected for measurement of vancomycin. The concentration, measured with a Beckman Coulter Synchron competitive turbidimetric immunoassay, was 0.1 mg/L. The result, which was incompatible with ongoing vancomycin therapy, signaled a problem to the technologist. No analytical issues were evident upon review of calibration, controls, and results for other chemistry tests performed on the same specimen. In an attempt to resolve an apparent falsely low result, a 1:1 mix of the specimen was made with the Beckman liquid comprehensive control serum (level 3, 30.4 mg/L) and demonstrated near complete recovery (result of mix after adjusting for dilution, 28.6 mg/L). However, a 1:1 mix with pooled patient serum containing vancomycin (11 mg/L) led to only 15% recovery (result of mix after adjustment for dilution, 1.7 mg/L). The specimen was subsequently sent to another laboratory, where a vancomycin concentration of 9.8 mg/L was measured by use of a competitive enzyme-finked immunoassay (Emit, Olympus).

GENERE
Scienza e natura
PUBBLICATO
2009
1 marzo
LINGUA
EN
Inglese
PAGINE
13
EDITORE
American Association for Clinical Chemistry, Inc.
DIMENSIONE
177,8
KB

Altri libri di Clinical Chemistry

Alcohol Abuse and Carbohydrate-Deficient Transferrin Analysis: Are Screening and Confirmatory Analysis Required?(Letters) (Letter to the Editor) Alcohol Abuse and Carbohydrate-Deficient Transferrin Analysis: Are Screening and Confirmatory Analysis Required?(Letters) (Letter to the Editor)
2002
Biological Variation of Vitamins in Blood of Healthy Individuals (Nutrition) Biological Variation of Vitamins in Blood of Healthy Individuals (Nutrition)
2005
Reproducibility of Blood Markers of Oxidative Status and Endothelial Function in Healthy Individuals (Technical Briefs) Reproducibility of Blood Markers of Oxidative Status and Endothelial Function in Healthy Individuals (Technical Briefs)
2003
Homocysteine and Folate Status in an Era of Folic Acid Fortification: Balancing Benefits, Risks, And B-Vitamins (Editorial) Homocysteine and Folate Status in an Era of Folic Acid Fortification: Balancing Benefits, Risks, And B-Vitamins (Editorial)
2008
Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs) Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs)
2005
D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004