What Is an Abnormal Test Strip Urinary Erythrocyte Concentration?(Technical Briefs) (Clinical Report) What Is an Abnormal Test Strip Urinary Erythrocyte Concentration?(Technical Briefs) (Clinical Report)

What Is an Abnormal Test Strip Urinary Erythrocyte Concentration?(Technical Briefs) (Clinical Report‪)‬

Clinical Chemistry 2004, March, 50, 3

    • 2,99 €
    • 2,99 €

Descrizione dell’editore

Although examination of urine for red blood cells (RBCs) by automated analysis of test strips is a common, precise, and efficient method with a maximum throughput of up to 300 test strips per hour (1), the reference interval for this procedure is uncertain. Most laboratories consider a negative result as normal, based on findings in referred patients and on population studies showing that urinary tract tumors and other serious diseases are found in those with even trace amounts of blood on test strips (2-4). In two population studies, dipsticks were positive for blood in 3% of men of all ages (3) and in 13% of those over 60 years (4). A few patients with blood in their urine were found to have urothelial malignancies, but most had only a trace amount of RBCs on initial testing, with re-testing yielding intermittently positive results (3, 4); intermittently positive results may be attributable in part to variations in the methodology used because visual inspection by technicians and by patients themselves is less sensitive and less precise than semiautomated reflectance readings of urinalysis dipsticks (5). Our laboratory receives complaints from physicians about the high frequency of hematuria in their patients. We are unaware of previous studies reporting the distribution of RBC concentrations in a healthy population tested by semiautomated reflectance readings. Recent studies using a urine flow cytometer (UF-100) suggest that the number of RBCs in the urine in healthy individuals should be in the range of 10-20 cells/[micro]L with even higher numbers on dipsticks, which also measure lysed cells (6-8). In the present study we analyzed the urine of 1000 men and women of various ages seen consecutively for screening examinations and used automated analysis of the test strips to determine the reference interval.

GENERE
Scienza e natura
PUBBLICATO
2004
1 marzo
LINGUA
EN
Inglese
PAGINE
9
EDITORE
American Association for Clinical Chemistry, Inc.
DIMENSIONE
176,3
KB

Altri libri di Clinical Chemistry

Alcohol Abuse and Carbohydrate-Deficient Transferrin Analysis: Are Screening and Confirmatory Analysis Required?(Letters) (Letter to the Editor) Alcohol Abuse and Carbohydrate-Deficient Transferrin Analysis: Are Screening and Confirmatory Analysis Required?(Letters) (Letter to the Editor)
2002
Biological Variation of Vitamins in Blood of Healthy Individuals (Nutrition) Biological Variation of Vitamins in Blood of Healthy Individuals (Nutrition)
2005
Reproducibility of Blood Markers of Oxidative Status and Endothelial Function in Healthy Individuals (Technical Briefs) Reproducibility of Blood Markers of Oxidative Status and Endothelial Function in Healthy Individuals (Technical Briefs)
2003
Homocysteine and Folate Status in an Era of Folic Acid Fortification: Balancing Benefits, Risks, And B-Vitamins (Editorial) Homocysteine and Folate Status in an Era of Folic Acid Fortification: Balancing Benefits, Risks, And B-Vitamins (Editorial)
2008
Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs) Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs)
2005
D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004