Effects of Tourniquet Technique, Order of Draw, And Sample Storage on Plasma Fibrinogen (Technical Briefs) Effects of Tourniquet Technique, Order of Draw, And Sample Storage on Plasma Fibrinogen (Technical Briefs)

Effects of Tourniquet Technique, Order of Draw, And Sample Storage on Plasma Fibrinogen (Technical Briefs‪)‬

Clinical Chemistry 1998, March, 44, 3

    • 2,99 €
    • 2,99 €

Publisher Description

The use of plasma fibrinogen concentrations to predict clinical ischemic events in subjects with and without prior evidence of atherosclerosis [1-14] has led to recommendations to incorporate fibrinogen into the cardiovascular risk profile [15]. Such use of plasma fibrinogen requires careful attention to potential sources of variability, as only small (5%) absolute differences in fibrinogen distinguish subjects who develop cardiovascular disease from those subjects who do not [16]. Variability in fibrinogen results apart from intraindividual differences is difficult to quantify, because the few groups who have examined these issues used different assays for fibrinogen determination. Moreover, the functional assay for fibrinogen is highly influenced by technician expertise and manipulation [17]. Previously, we examined within-run analytical CV, within-person, within-day biological variation, and a 6-week within-person biological variation with the Clauss method for fibrinogen determination [16].

GENRE
Science & Nature
RELEASED
1998
1 March
LANGUAGE
EN
English
LENGTH
11
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SIZE
180.8
KB

More Books by Clinical Chemistry

D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004
Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs) Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs)
2005
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs) Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs)
2005
Newborn Screening for Lysosomal Storage Disorders (Editorials) Newborn Screening for Lysosomal Storage Disorders (Editorials)
2005
Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor) Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor)
2005