Quality Assessment of Coaguchek Point-Of-Care Prothrombin Time Monitors: Comparison of the European Community--Approved Procedure and Conventional External Quality Assessment (Overview) Quality Assessment of Coaguchek Point-Of-Care Prothrombin Time Monitors: Comparison of the European Community--Approved Procedure and Conventional External Quality Assessment (Overview)

Quality Assessment of Coaguchek Point-Of-Care Prothrombin Time Monitors: Comparison of the European Community--Approved Procedure and Conventional External Quality Assessment (Overview‪)‬

Clinical Chemistry 2006, Oct, 52, 10

    • 12,99 zł
    • 12,99 zł

Publisher Description

CoaguChek point-of-care testing is used widely for prothrombin time (PT) [6] testing in Germany and in The Netherlands and on an increasing scale in the United Kingdom, other European countries, and North America. CoaguChek monitors must give reliable displayed international normalized ratios (INR) within the 2.0-4.5 interval, because there is a dramatic increase in the risk of thrombotic and bleeding complications, respectively, at INR 2.0 and 4.5 (1). Recent reports have reiterated the need for reliable quality assessment (QA) of CoaguChek monitors (2, 3). Hitherto, no readily available system has existed for the local QA of CoaguChek monitors. Local QA is essential because International Sensitivity Index (ISI) calibration of individual monitors by the WHO ISI method (4) is not feasible. This is because of the need in ISI calibration for parallel conventional manual PT testing with the local PT test system (instrument/thromboplastin combination) and an international reference thromboplastin on plasma from the same whole blood samples used in tests on the CoaguChek. We report here on a joint study by the European Concerted Action on Thrombosis and the European Concerted Action on Anticoagulation (ECAA; now known as the European Action on Anticoagulation). The goal of this study was to assess the reliability of the European Community (EC)-approved QA method and compare it with conventional QA analysis.

GENRE
Science & Nature
RELEASED
2006
1 October
LANGUAGE
EN
English
LENGTH
15
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SIZE
224.8
KB

More Books by Clinical Chemistry

D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004
Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs) Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs)
2005
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs) Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs)
2005
Newborn Screening for Lysosomal Storage Disorders (Editorials) Newborn Screening for Lysosomal Storage Disorders (Editorials)
2005
Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor) Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor)
2005