Cardiac Troponin T in Serum As Marker for Myocardial Injury in Newborns (Technical Briefs) Cardiac Troponin T in Serum As Marker for Myocardial Injury in Newborns (Technical Briefs)

Cardiac Troponin T in Serum As Marker for Myocardial Injury in Newborns (Technical Briefs‪)‬

Clinical Chemistry 1997, August, 43, 8

    • 29,00 kr
    • 29,00 kr

Utgivarens beskrivning

In neonates, acute perinatal asphyxia may lead to ischemic myocardial damage [1]. In some cases, subendocardial infarction has been documented [2]. Generally, diagnosis of the myocardial injury (MI) is based on clinical findings, suggestive electrocardiographic and echocardiographic patterns [3], decrease in myocardial uptake of thallium [4], and classical creatine kinase (CK)-MB isoenzyme measurement [5]. However, CK-MB in serum cannot be regarded as a cardiac-specific marker in the neonate, and extreme caution should be used in the interpretation of increased CK-MB activity during this period [6]. Cardiac troponin T (cTnT), the structural protein that binds the troponin complex to the tropomyosin molecular strand, has recently been proposed as a more specific biochemical marker for diagnosis of myocardial infarction in the adult population [7]. Here we evaluated the use of cTnT measurement in serum in the diagnosis of MI in newborns, as well as that of the determination of CK-MB mass concentration by a sensitive and specific monoclonal anti-CK-MB antibody-based immunoassay. Three groups of infants were studied. Group I consisted of 27 preterm infants (gestational age ranging from 28 to 36 weeks) without major respiratory and cardiovascular dysfunctions. Group II was 27 healthy full-term newborns (15 born by vaginal delivery and 12 by cesarean section) with a mean gestational age of 39.7 weeks. Group III was composed of seven infants (four preterm and three term) who demonstrated, during the first 3 days after birth, clinical, electrocardiographic, and echocardiographic signs of MI. In particular, in electrocardiogram (ECG) evaluation, MI was considered to be present when inversion of T waves or ST-segment depression [greater than or equal to]1 mm in more than two precordial leads was noted. Groups I and II underwent a clinical examination, ECG, echocardiogram, and blood collection for the measurement of total CK, CK-MB, and cTnT on day 2 after birth. Group III was evaluated with ECG and echocardiography at presentation and every 24 h until clinical recovery or death. Total CK, CK-MB, and cTnT were measured 12 and 48 h after presentation and, when possible, after 45 days. The protocol of the study was approved by the local Ethical Committee, and parental consent was obtained.

GENRE
Vetenskap och natur
UTGIVEN
1997
1 augusti
SPRÅK
EN
Engelska
LÄNGD
10
Sidor
UTGIVARE
American Association for Clinical Chemistry, Inc.
STORLEK
174,5
KB

Fler böcker av Clinical Chemistry

D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report) D-Dimer Testing for Deep Venous Thrombosis: A Metaanalysis (Clinical Report)
2004
Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs) Congenital Analbuminemia Attributable to Compound Heterozygosity for Novel Mutations in the Albumin Gene (Technical Briefs)
2005
Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs) Highly Sensitive Immunoprecipitation Method for Extracting and Concentrating Low-Abundance Proteins from Human Serum (Technical Briefs)
2005
Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs) Measurement of Pro-C-Type Natriuretic Peptide in Plasma (Technical Briefs)
2005
Newborn Screening for Lysosomal Storage Disorders (Editorials) Newborn Screening for Lysosomal Storage Disorders (Editorials)
2005
Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor) Inadequate Attempts to Measure the Microheterogeneity of Transthyretin by Low-Resolution Mass Spectrometry (Letters) (Letter to the Editor)
2005