Components of Total Measurement Error for Hemoglobin [A.Sub.1C] (Technical Briefs) (Clinical Report) Components of Total Measurement Error for Hemoglobin [A.Sub.1C] (Technical Briefs) (Clinical Report)

Components of Total Measurement Error for Hemoglobin [A.Sub.1C] (Technical Briefs) (Clinical Report‪)‬

Clinical Chemistry 2001, Oct, 47, 10

    • US$5.99
    • US$5.99

출판사 설명

The Diabetes Control and Complications Trial (DCCT) and the UK Prospective Diabetes Study (UKPDS), undertaken in people with type 1 and 2 diabetes, respectively (1, 2), established the significance of glycohemoglobin (gHb), and in particular hemoglobin [A.sub.1c] ([HbA.sub.1c], as a prognostic indicator for long-term micro- and macrovascular complications. However, the [HbA.sub.1c] measured during the DCCT and UKPDS represents a gHb fraction characterized by its retention time on cation-exchange HPLC rather than its unique chemical structure (deoxyfructosylhemoglobin). Accordingly, the DCCT [HbA.sub.1c] procedure represents a selective, but not a specific assay method (3). Because no definitive or reference method exists for quantification of [HbA.sub.1c] (4), the American Diabetes Association (ADA), in collaboration with the Association of Clinical Chemists, implemented the National Glycohemoglobin Standardization Program (NGSP) (5) to standardize [HbA.sub.1c] values determined by methods different from that used in the DCCT. The ADA (6) now states that their recommended [HbA.sub.1c] thresholds, with respect to patient management goals, are valid only for NGSP-certified methods.

장르
과학 및 자연
출시일
2001년
10월 1일
언어
EN
영어
길이
9
페이지
출판사
American Association for Clinical Chemistry, Inc.
판매자
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
크기
174.3
KB
Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor) Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor)
2006년
Variability of Serial Lipoprotein-Associated Phospholipase [A.Sub.2] Measurements in Post-Myocardial Infarction Patients: Results from the AIRGENE Study Center Augsburg (Lipids, Lipoproteins, And Cardiovascular Risk Factors) (Clinical Report) Variability of Serial Lipoprotein-Associated Phospholipase [A.Sub.2] Measurements in Post-Myocardial Infarction Patients: Results from the AIRGENE Study Center Augsburg (Lipids, Lipoproteins, And Cardiovascular Risk Factors) (Clinical Report)
2008년
Electrospray Mass Spectrometry for Measurement of Glycohemoglobin (Editorial) (Clinical Report) Electrospray Mass Spectrometry for Measurement of Glycohemoglobin (Editorial) (Clinical Report)
1997년
Contemporary Practice in Clinical Chemistry Contemporary Practice in Clinical Chemistry
2020년
The Handbook of Metabolic Phenotyping The Handbook of Metabolic Phenotyping
2018년
Molecular Epidemiology of Chronic Diseases Molecular Epidemiology of Chronic Diseases
2011년
Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs) Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs)
2005년
C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics) C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics)
2001년
Ghrelin, Leptin, IGF-1, IGFBP-3, and Insulin Concentrations at Birth: Is There a Relationship with Fetal Growth and Neonatal Anthropometry?(Pediatric Clinical Chemistry) Ghrelin, Leptin, IGF-1, IGFBP-3, and Insulin Concentrations at Birth: Is There a Relationship with Fetal Growth and Neonatal Anthropometry?(Pediatric Clinical Chemistry)
2008년
Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial) Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial)
1997년
Transferrin Saturation and Screening of Genetic Hemochromatosis (Letters) (Letter to the Editor) Transferrin Saturation and Screening of Genetic Hemochromatosis (Letters) (Letter to the Editor)
1998년
Effect of Riboflavin Status on the Homocysteine-Lowering Effect of Folate in Relation to the MTHFR (C677T) Genotype (Nutrition) Effect of Riboflavin Status on the Homocysteine-Lowering Effect of Folate in Relation to the MTHFR (C677T) Genotype (Nutrition)
2003년