Interlaboratory Variation of Plasma Total Homocysteine Measurements: Results of Three Successive Homocysteine Proficiency Testing Surveys (General Clinical Chemistry) Interlaboratory Variation of Plasma Total Homocysteine Measurements: Results of Three Successive Homocysteine Proficiency Testing Surveys (General Clinical Chemistry)

Interlaboratory Variation of Plasma Total Homocysteine Measurements: Results of Three Successive Homocysteine Proficiency Testing Surveys (General Clinical Chemistry‪)‬

Clinical Chemistry 2002, Sept, 48, 9

    • $5.99
    • $5.99

Publisher Description

In recent years, the measurement of plasma total homocysteine (tHcy) [1] and its association with cardiovascular and thromboembolic diseases have received considerable attention. In the last decade, numerous epidemiologic studies have demonstrated that moderately increased tHcy, whether measured after fasting or 2-6 h after a methionine load, is associated with an increased risk for coronary artery disease (CAD)(1-5). It has also been indicated that plasma tHcy concentrations are a strong predictor of mortality in patients with angiographically confirmed CAD (6, 7). In addition, high plasma tHcy concentrations have been reported to be a risk factor for deep-vein thrombosis in the general population (8-10). As a result of these studies, the volume of tHcy testing in clinical laboratories has grown steadily during the last decade. Initially, tHcy was measured with amino acid analyzers, using the ninhydrin reaction as the method of detection. These methods were generally insensitive, and HPLC with fluorometric detection (HPLC-FD) became the method of choice (11). Such methods are based on the reduction of protein-bound homocysteine, homocystine, and mixed disulfides to reduced homocysteine, followed by derivatization of the reduced homocysteine with thiol-specific fluorogenic reagents. HPLC with electrochemical detection (HPLC-ED) is also used and has the advantage that no derivatization of the sample is required before detection (11). More recently, commercially available automated immunoassays have been introduced. They include the microtiter plate enzyme immunoassay (12) and the fluorescence polarization immunoassay (FPIA) on the Abbott IMx[R] analyzer (13). Both methods are based on enzymatic conversion of homocysteine to S-adenosyl-L-homocysteine, which is subsequently detected by a competitive immunoassay. Gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) methods have also recently been reported (11,14,15). These methods are used for the routine quantification of tHcy in some laboratories and may be useful in the standardization of plasma tHcy assays. In particular, the LC-MS/MS method has been suggested as a reference method (11).

GENRE
Science & Nature
RELEASED
2002
September 1
LANGUAGE
EN
English
LENGTH
22
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SELLER
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
SIZE
237.9
KB

More Books Like This

Can Whole-Blood Samples Be Stored over 24 Hours Without Compromising Stability of C-Reactive Protein, Retinol, Ferritin, Folic Acid, And Fatty Acids in Epidemiologic Research?(Technical Briefs) (Clinical Report) Can Whole-Blood Samples Be Stored over 24 Hours Without Compromising Stability of C-Reactive Protein, Retinol, Ferritin, Folic Acid, And Fatty Acids in Epidemiologic Research?(Technical Briefs) (Clinical Report)
2005
Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor) Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor)
2006
Dilution Protocols for Detection of Hook Effects/Prozone Phenomenon (Letters) (Letter to the Editor) Dilution Protocols for Detection of Hook Effects/Prozone Phenomenon (Letters) (Letter to the Editor)
2000
Contemporary Practice in Clinical Chemistry Contemporary Practice in Clinical Chemistry
2020
Principles and Applications of Clinical Mass Spectrometry Principles and Applications of Clinical Mass Spectrometry
2018
Fundamentals of Analytical Toxicology Fundamentals of Analytical Toxicology
2020

More Books by Clinical Chemistry

Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs) Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs)
2005
Ghrelin, Leptin, IGF-1, IGFBP-3, and Insulin Concentrations at Birth: Is There a Relationship with Fetal Growth and Neonatal Anthropometry?(Pediatric Clinical Chemistry) Ghrelin, Leptin, IGF-1, IGFBP-3, and Insulin Concentrations at Birth: Is There a Relationship with Fetal Growth and Neonatal Anthropometry?(Pediatric Clinical Chemistry)
2008
C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics) C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics)
2001
Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial) Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial)
1997
Transferrin Saturation and Screening of Genetic Hemochromatosis (Letters) (Letter to the Editor) Transferrin Saturation and Screening of Genetic Hemochromatosis (Letters) (Letter to the Editor)
1998
Effect of Riboflavin Status on the Homocysteine-Lowering Effect of Folate in Relation to the MTHFR (C677T) Genotype (Nutrition) Effect of Riboflavin Status on the Homocysteine-Lowering Effect of Folate in Relation to the MTHFR (C677T) Genotype (Nutrition)
2003