The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments (Special Report) (Polymerase Chain Reaction) (Report) The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments (Special Report) (Polymerase Chain Reaction) (Report)

The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR Experiments (Special Report) (Polymerase Chain Reaction) (Report‪)‬

Clinical Chemistry 2009, April, 55, 4

    • $5.99
    • $5.99

Publisher Description

The fluorescence-based quantitative real-time PCR (qPCR) (15) (1-3), with its capacity to detect and measure minute amounts of nucleic acids in a wide range of samples from numerous sources, is the enabling technology par excellence of molecular diagnostics, life sciences, agriculture, and medicine (4, 5). Its conceptual and practical simplicity, together with its combination of speed, sensitivity, and specificity in a homogeneous assay, have made it the touchstone for nucleic acid quantification. In addition to its use as a research tool, many diagnostic applications have been developed, including microbial quantification, gene dosage determination, identification of transgenes in genetically modified foods, risk assessment of cancer recurrence, and applications for forensic use (6-11). This popularity is reflected in the prodigious number of publications reporting qPCR data, which invariably use diverse reagents, protocols, analysis methods, and reporting formats. This remarkable lack of consensus on how best to perform qPCR experiments has the adverse consequence of perpetuating a string of serious shortcomings that encumber its status as an independent yardstick (12). Technical deficiencies that affect assay performance include the following: (a) inadequate sample storage, preparation, and nucleic acid quality, yielding highly variable results; (b) poor choice of reverse-transcription primers and primers and probes for the PCR, leading to inefficient and less-than-robust assay performance; and (c) inappropriate data and statistical analyses, generating results that can be highly misleading. Consequently, there is the real danger of the scientific literature being corrupted with a multitude of publications reporting inadequate and conflicting results (13). The publication (14) and retraction (15) of a Science "Breakthrough of the Year 2005" report provides a disquieting warning. The problem is exacerbated by the lack of information that characterizes most reports of studies that have used this technology, with many publications not providing sufficient experimental detail to permit the reader to critically evaluate the quality of the results presented or to repeat the experiments. Specifically, information about sample acquisition and handling, RNA quality and integrity, reverse-transcription details, PCR efficiencies, and analysis parameters are frequently omitted, whereas sample normalization is habitually carried out against single reference genes without adequate justification.

GENRE
Science & Nature
RELEASED
2009
April 1
LANGUAGE
EN
English
LENGTH
38
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SELLER
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
SIZE
255.1
KB

More Books Like This

MIQE & qPCR MIQE & qPCR
2016
MIQE qPCR & dPCR MIQE qPCR & dPCR
2022
Polymerase Chain Reaction (PCR) : Principle To Practices Polymerase Chain Reaction (PCR) : Principle To Practices
2016
Fundamentals of Advanced Omics Technologies: From Genes to Metabolites Fundamentals of Advanced Omics Technologies: From Genes to Metabolites
2014
Definitive qPCR Definitive qPCR
2012
Applications of Advanced Omics Technologies: From Genes to Metabolites Applications of Advanced Omics Technologies: From Genes to Metabolites
2014

More Books by Clinical Chemistry

Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs) Genetic Variation in the MTHFR Gene Influences Thiopurine Methyltransferase Activity (Technical Briefs)
2005
Ghrelin, Leptin, IGF-1, IGFBP-3, and Insulin Concentrations at Birth: Is There a Relationship with Fetal Growth and Neonatal Anthropometry?(Pediatric Clinical Chemistry) Ghrelin, Leptin, IGF-1, IGFBP-3, and Insulin Concentrations at Birth: Is There a Relationship with Fetal Growth and Neonatal Anthropometry?(Pediatric Clinical Chemistry)
2008
C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics) C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics)
2001
Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial) Doping in Sport: Misuse, Analytical Tests, And Legal Aspects (Editorial)
1997
Transferrin Saturation and Screening of Genetic Hemochromatosis (Letters) (Letter to the Editor) Transferrin Saturation and Screening of Genetic Hemochromatosis (Letters) (Letter to the Editor)
1998
Effect of Riboflavin Status on the Homocysteine-Lowering Effect of Folate in Relation to the MTHFR (C677T) Genotype (Nutrition) Effect of Riboflavin Status on the Homocysteine-Lowering Effect of Folate in Relation to the MTHFR (C677T) Genotype (Nutrition)
2003