Evaluation and Performance Characteristics of the STA-R Coagulation Analyzer (Technical Briefs) Evaluation and Performance Characteristics of the STA-R Coagulation Analyzer (Technical Briefs)

Evaluation and Performance Characteristics of the STA-R Coagulation Analyzer (Technical Briefs‪)‬

Clinical Chemistry 2002, Sept, 48, 9

    • $5.99
    • $5.99

Publisher Description

Recently, increasing coagulation test volume and tight personnel budgets have increased interest in automated coagulation analyzers (1). The first coagulation instrument, the Fibrometer (Becton Dickinson), used a moving electrode to detect the clot. This brought some degree of standardization to the reading of the clotting endpoint, but this method was labor-intensive. The next phase in instrumentation was semiautomation. These instruments had storage and delivery capabilities for reagents, but manual pipetting was required for the samples. Examples of semiautomated instruments include the Coag-A-Mate X-2 (General Diagnostics) (2) and early models of the MLA (Medical Laboratory Automation). The current generation of coagulation instrumentation is fully automated. Their capabilities include primary tube sampling, automatic rerun and dilution capabilities, and clotting, chromogenic, and immunologic methodologies (3). Examples of this type of instrumentation include the MDA (bioMerieux), STA-R (Diagnostica Stago), AMAX (Sigma Diagnostics), BCS (Dade Behring), and the Sysmex CA6000 (Dade International) (4). We summarize our technical evaluation of the STA-R. The evaluation addressed several issues, including ease of operation, methodologies available, reagent and patient sample on-board capabilities, ability to perform automatic dilutions, and validation of performance.

GENRE
Science & Nature
RELEASED
2002
1 September
LANGUAGE
EN
English
LENGTH
10
Pages
PUBLISHER
American Association for Clinical Chemistry, Inc.
SELLER
The Gale Group, Inc., a Delaware corporation and an affiliate of Cengage Learning, Inc.
SIZE
176.7
KB

More Books Like This

Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor) Can Heparin Plasma Be Used Instead of Serum for Nephelometric Analysis of Serum Proteins?(Letters) (Letter to the Editor)
2006
Bias and Random Error in Retinol Measurements of Laboratories in Countries with Populations with Mild to Severe Vitamin A Deficiency (Technical Briefs) Bias and Random Error in Retinol Measurements of Laboratories in Countries with Populations with Mild to Severe Vitamin A Deficiency (Technical Briefs)
2002
Dilution Protocols for Detection of Hook Effects/Prozone Phenomenon (Letters) (Letter to the Editor) Dilution Protocols for Detection of Hook Effects/Prozone Phenomenon (Letters) (Letter to the Editor)
2000
Quick Guide to Body Fluid Testing Quick Guide to Body Fluid Testing
2023
Principles and Applications of Clinical Mass Spectrometry Principles and Applications of Clinical Mass Spectrometry
2018
Cytogenetic Laboratory Management Cytogenetic Laboratory Management
2017

More Books by Clinical Chemistry

Lowering Cutoffs for Initial and Confirmation Testing for Cocaine and Marijuana: Large-Scale Study of Effects on the Rates of Drug-Positive Results (Drug Monitoring and Toxicology) Lowering Cutoffs for Initial and Confirmation Testing for Cocaine and Marijuana: Large-Scale Study of Effects on the Rates of Drug-Positive Results (Drug Monitoring and Toxicology)
1997
Myocardial Infarction Redefined: Role of Cardiac Troponin Testing (Editorial) Myocardial Infarction Redefined: Role of Cardiac Troponin Testing (Editorial)
2001
Distribution of Fasting Plasma Insulin, Free Fatty Acids, And Glucose Concentrations and of Homeostasis Model Assessment of Insulin Resistance in a Representative Sample of Quebec Children and Adolescents (Pediatric Clinical Chemistry) Distribution of Fasting Plasma Insulin, Free Fatty Acids, And Glucose Concentrations and of Homeostasis Model Assessment of Insulin Resistance in a Representative Sample of Quebec Children and Adolescents (Pediatric Clinical Chemistry)
2003
C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics) C677T and AI298C Polymorphisms of the Methylenetetrahydrofolate Reductase Gene: Incidence and Effect of Combined Genotypes on Plasma Fasting and Post-Methionine Load Homocysteine in Vascular Disease (Molecular Diagnostics and Genetics)
2001
Acetylcholinesterase Activity and Biogenic Amines in Phenylketonuria (Technical Briefs) Acetylcholinesterase Activity and Biogenic Amines in Phenylketonuria (Technical Briefs)
2002
Homocysteine, 5, 10-Methylenetetrahydrofolate Reductase 677CT Polymorphism, Nutrient Intake, And Incident Cardiovascular Disease in 24 968 Initially Healthy Women (Molecular Diagnostics and Genetics) (Clinical Report) Homocysteine, 5, 10-Methylenetetrahydrofolate Reductase 677CT Polymorphism, Nutrient Intake, And Incident Cardiovascular Disease in 24 968 Initially Healthy Women (Molecular Diagnostics and Genetics) (Clinical Report)
2007